The original mechanical fastening system for Polymer Modified (PM) and Modified Polymer Based (PB) EIFS systems. Use Grid-Mate for attaching lath, fabric and wire mesh over rigid insulation to wood, steel, masonry or concrete.
FEATURES
Keying windows provide a strong bond with all
coatings.
Available with stem for time saving
pre-spotting
of the plate.
Climacoat® and Climaseal® fasteners for corrosion
resistance.
MODELS
INSTALLATION STEPS
APPLICATIONS
DOWNLOAD
GRID-MATE
PART NO.
DESCRIPTION
APPLICATION
2115900
Grid-Mate Washer
--
2117900
Grid-Mate with Stem
--
Fasteners
2311500
7 x 1-5/8”
Wood/Light Metal
2312500
8 x 2”
Wood/Light Metal
2313500
8 x 2-1/2”
Wood/Light Metal
2314500
8 x 3”
Wood/Light Metal
2315500
8 x 4”
Wood/Light Metal
2316500
10 x 5”
Wood/Light Metal
2317500
10 x 6”
Wood/Light Metal
2321500
6 x 1-5/8”
Steel Framing
2318500
6 x 2”
Steel Framing
2319500
8 x 2-5/8”
Steel Framing
2320500
8 x 3”
Steel Framing
2322500
10 x 4”
Steel Framing
2323500
10 x 5”
Steel Framing
STEP 1:
Use a 0-2500 RPM, 6 amp min. rated screw gun or cordless drill to install fasteners to wood and steel substrates.
STEP 2: Seat Grid-Mate washers flush with or maximum 1/16” below insulation surface. Over-driving may damage the washer and insulation.
STEP 3: Fasteners must penetrate steel substrates a minimum of 3 pitches of threads.
STEP 4: Replace worn or damaged bit tips to prevent damage to fastener head and its finish.
STEP 5: Consult EIFS system manufacturers’ specifications for appropriate fastener spacing.